LF03

LIGHTING MAINTENANCE LIFT

Introduction

Introduction

LF03

LIGHTING MAINTENANCE LIFT

Wireless remote control suspension wizard is simple, easy and low risk

Use the remote control to lower the lamps suspended at high altitudes in stadiums, factories, stations, etc. to the ground to facilitate future maintenance and replacement of lamps and eliminate the danger of high-altitude operations.

Specifications

  • Luminaire dimension          220 x 220 x 605 mm
  • Net weight          10kg
  • Lifting power          50W
  • Lifting height                15M . Max
  • Load                5KG~15KG
  • Rated voltage                AC110V / 220V 60HZ    
  • Average rising rate       ≦ 2.0M / min    
  • Average falling rate       ≦ 2.3M / min    
  • Number of remote controls              32 units
  • Remote control distance               30M . Max  
  • Support control system      DALI
  •   

Material

  • Ontology   Aluminum extrusion
  • Trim cover        Stainless steel

Product features

High-strength steel wire rope can be extended up to 15M.

It can hang 5~15kg lamps. During the descending stroke, if there are objects blocking the descent or reaching the ground, the lift will automatically stop the descending action, making maintenance safe and reliable.

The aluminum extruded material body has good heat dissipation, thickness is 3.5mm, and the surface is treated with powder baking paint. The load fuse device can activate the protection machine when the load is abnormal to prevent damage to the machine.

Use double steel cables to lift, and the weight of the steel cables is reduced by half.

Using the lifting ring installation and fixation method, the installation is quick and convenient. The elevator remote control can control up to 32 elevators at a time, and the maximum remote control distance is 30m.

Use the remote control to lower the lamps or equipment suspended at high altitudes such as stadiums, factories, stations, etc. to the ground to facilitate future maintenance and replacement of lamps and eliminate the danger of high-altitude operations.

In the stopped state, if the remote control is not used for more than 10 minutes, the host will automatically enter the protection state. You can use the stop button on the remote control to release the protection state, and then perform the rising and falling actions.


Installation method

Installation and fixation of lifting rings




Photos

Downloads

Documents

Name

Updated date

File size

Download

  • Name

    LF03_Catalog

    Updated date

    2024-02-22

    File size

    1MB

    Download